Digital Mobile Pump Controller , Water Level Controller For Submersible Pump


Product Details:

Certification: CE
Model Number: M931
Packaging Details: paper carton

Detailed Product Description

Phase: Three Phase Pump Controlled Quantity: One Pump
Enclosure Protection Grade: IP54 Displaying: LCD Display
Trip Response Time Of Over Load: 5sec-5min Trip Response Time Of Short Circuit: <0.1sec
Trip Response Time Of Under / Over Voltage: <5sec Trip Response Time Of Dry Run: :6sec
Recovery Time Of Over Load: 30min Recovery Time Of Under / Over Voltage: 5min
Recovery Time Of Dry Run: 30min Trip Voltage Of Over Voltage: 437V
Trip Voltage Of Under Voltage: 301V Liquid Level Transfer Distance: <150m

Digital Three Phase Submersible Pump Controller – Auto And Manual,0.75-15KW ,With One Button Calibration.

Products Brief :
M931 is applied for automatic liquid level control / pressure control and effective protection for single pump of with AC380V, 50hz, three phase output power 0.75KW-15KW (1HP-20HP),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.

Model M931 has many operation modes by adopting different electric installations. An important feature that makes the difference between Model M931 and common On/Off pump control box is the probe / sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe / sensor in the well.

Model M931 is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.

Main Technical Specifications
■Rated Input Voltage…………………………………………………AC380V / Three Phase
■ Rated Frequency…………………………………………50Hz-60Hz (at option)
■ Rated Output Power of Motor…………………0.75-4KW / 5.5-11KW/15KW(at option)
■ Open Phase Trip Response Time…….……………………2sec
■ Short Circuit Trip Response Time……………………………………………0.1sec
■ Dry Running Trip Response Time………………………………………………6sec
■ Over / Under Voltage Trip Response Time……………………………………5sec
■ Pump Stalled Trip Response Time……………………..………0.5sec
■ Over Current Trip Response Time……………………………………5sec-5min
■ Recovery Time of Over / Under Voltage……………………………………2min
■ Recovery Time of Over Current…………………………………………30min
■ Recovery Time of Dry Running.………………………………………………30min
■ Over / Under Voltage Trip……..……………………………….………………±15%
■ Dry Running Trip……………………………………………….70%
■ Pump Stalled Trip………………………………………….……………………200%

① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)
② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)

Model M931
Main technical data
.Start type Direct on line
. Qty of controlled pump Single pump
. Protection method Real motor running ampere
. Rated input voltage: AC380V Three phase

50HZ/ 60HZ

. Rated output power: 0. 75kw-4kw (1 hp-5. 5hp)
5. 5kw-11kw (7.5hp-15hp)15kw(20hp)
Protection function Over load protection
Pump stalled protection
Dry run protection with sensor free
Under voltage protection
Over voltage protection
Rapid cycle protection
Phase unbalance protection
Phase reversal protection
Open phase protection
Application &
Control characteristic
Control and protect universal pump
Using water level sensor ,float switch or pressure switch to control pump start and stop
Applied for water supply by liquid level control through float switch or liquid probe
Applied for water supply by pressure control through pressure switch and pressure tank
Applied for drainage by liquid level control through float switch or liquid probe
Other features Pump last five faults record displaying
Pump accumulative running time displaying
Pump shaft anti-rust
LCD screen locked function under auto state
Present RS485 port
Main installation data
Working temperature
Working humidity
Degree of protection
Install position
Unit dimension (L x W x H)
-25℃– +55℃
20%–90%RH, no drips concreted
IP54
Wall mounting
250×1 97×114cm
Phase

Three