{"id":172,"date":"2019-11-11T18:34:26","date_gmt":"2019-11-11T18:34:26","guid":{"rendered":"http:\/\/maxitech.ca\/?post_type=product&#038;p=172"},"modified":"2019-12-06T20:28:32","modified_gmt":"2019-12-06T20:28:32","slug":"duplex-sump-pump-controller-water-pump-motor-controller-short-circuit-protection","status":"publish","type":"product","link":"https:\/\/maxitech.ca\/water\/product\/duplex-sump-pump-controller-water-pump-motor-controller-short-circuit-protection\/","title":{"rendered":"Duplex Sump Pump Controller , Water Pump Motor Controller Short Circuit Protection"},"content":{"rendered":"<div id=\"anchor_product_desc\" class=\"no_product_detaildesc\">\n<p style=\"color: tomato;\"><strong>Detailed Product Description<\/strong><\/p>\n<table class=\"details_table\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Phase:<\/th>\n<td>Three Phase<\/td>\n<th>Pump Controlled Quantity:<\/th>\n<td>Two Pumps<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>Enclosure Protection Grade:<\/th>\n<td>IP54<\/td>\n<th>Install Position:<\/th>\n<td>Wall Mounting<\/td>\n<\/tr>\n<tr>\n<th>Displaying ::<\/th>\n<td>LCD Display<\/td>\n<th>Liquid Level Transfer Distance:<\/th>\n<td>\u22641000m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"details_wrap\">\n<p><strong>Digital Three Phase Water Pump Control Panel &#8211; Auto And Manual,00.75-15KW ,With One Button Calibration.<\/strong><\/p>\n<p style=\"color: tomato;\"><strong>Products Brief :<\/strong><\/p>\n<p><strong>L932<\/strong> is applied for automatic liquid level control \/ pressure control and effective protection for duplex pumps of with AC380V, 50hz, single phase output power 0.75KW-15KW (1HP-20HP),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.<br \/>\n<strong>Model L932<\/strong> has many operation modes by adopting different electric installations. An important feature that makes the difference between Model L932 and common On\/Off pump control box is the probe \/ sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe \/ sensor in the well.<br \/>\n<strong>Model L932<\/strong> is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.<\/p>\n<p><strong>Main Technical Specifications<\/strong><br \/>\n\u25a0Rated Input Voltage\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026AC380V \/ Three Phase<br \/>\n\u25a0 Rated Frequency\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u202650Hz-60Hz (at option)<br \/>\n\u25a0 Rated Output Power of Motor\u2026\u2026\u2026\u2026\u2026\u2026\u20260.75-4KW \/ 5.5-11KW\/15KW(at option)<br \/>\n\u25a0 Open Phase Trip Response Time\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20262sec<br \/>\n\u25a0 Short Circuit Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20260.1sec<br \/>\n\u25a0 Dry Running Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20266sec<br \/>\n\u25a0 Over \/ Under Voltage Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20265sec<br \/>\n\u25a0 Pump Stalled Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026..\u2026\u2026\u20260.5sec<br \/>\n\u25a0 Over Current Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20265sec-5min<br \/>\n\u25a0 Recovery Time of Over \/ Under Voltage\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20262min<br \/>\n\u25a0 Recovery Time of Over Current\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u202630min<br \/>\n\u25a0 Recovery Time of Dry Running.\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u202630min<br \/>\n\u25a0 Over \/ Under Voltage Trip\u2026\u2026..\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u00b115%<br \/>\n\u25a0 Dry Running Trip\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.70%<br \/>\n\u25a0 Pump Stalled Trip\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026200%<\/p>\n<p>\u2460 the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br \/>\n\u2461 Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)<br \/>\n\u2462 Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)<br \/>\n\u2463 Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)<\/p>\n<table style=\"width: 650px; word-wrap: break-word;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 182px;\"><strong>Model<\/strong><\/td>\n<td style=\"width: 523px;\">L932<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Main technical data<\/strong><\/td>\n<td style=\"width: 523px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Start type<\/strong><\/td>\n<td style=\"width: 523px;\">Direct on line<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Qty of controlled pump<\/strong><\/td>\n<td style=\"width: 523px;\">Two pumps<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Rated input voltage:<\/strong><\/td>\n<td style=\"width: 523px;\">AC380V Single phase<br \/>\n50HZ\/ 60HZ<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Rated output power:<\/strong><\/td>\n<td style=\"width: 523px;\">0.75KW-15KW (1HP-20HP)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Capacitor:<\/strong><\/td>\n<td style=\"width: 523px;\">N\/M<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Protection Offered:<\/strong><\/td>\n<td style=\"width: 523px;\">Dry run<br \/>\nOver load<br \/>\nTransient surge<br \/>\nUnder voltage<br \/>\nOver voltage<br \/>\nOpen phase<br \/>\nPump shaft rust protection<br \/>\nPump stalled<br \/>\nShort circuit<br \/>\nOver temp<br \/>\nThree phase unbalance<br \/>\nPhase reversal<br \/>\nRepeated start<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Application &amp; <\/strong><strong>Control chara<\/strong><strong>c<\/strong><strong>teristic<\/strong><\/td>\n<td style=\"width: 523px;\">Control and protect universal pump<br \/>\nUsing water level sensor or float switch to control pump start and stop<br \/>\nApplied for water supply by liquid level control through float switch or liquid probe<br \/>\nApplied for water supply by pressure control through pressure switch and pressure tank<br \/>\nApplied for drainage by liquid level control through float switch or liquid probe<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Other features<\/strong><\/td>\n<td style=\"width: 523px;\">Push button calibration<br \/>\nMemory function when power off &amp; recovery<strong>Interactive LCD Screen<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Main installation data<\/strong><\/td>\n<td style=\"width: 523px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 182px;\"><strong>Working temperature<\/strong><br \/>\n<strong>Working humidity<\/strong><br \/>\n<strong>Degree of protection<\/strong><br \/>\n<strong>Install position<\/strong><br \/>\n<strong>Unit dimension (L x W x H)<\/strong><\/td>\n<td style=\"width: 523px;\">-25\u2103&#8211; +55\u2103<br \/>\n20%&#8211;90%RH, no drips concreted<br \/>\nIP22<br \/>\nWall mounting<br \/>\n1 70\u00d7 1 55\u00d7 8.5mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"clearfix10\"><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p class=\"txt_box\" style=\"color: tomato;\"><strong>Product Details:<\/strong><\/p>\n<table class=\"tables data\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th width=\"35%\">Certification:<\/th>\n<td>CE<\/td>\n<\/tr>\n<tr>\n<th width=\"35%\">Model Number:<\/th>\n<td>L932<\/td>\n<\/tr>\n<tr>\n<th nowrap=\"nowrap\" width=\"35%\">Packaging Details:<\/th>\n<td>Carton<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":175,"template":"","meta":[],"product_brand":[],"product_cat":[15,18],"product_tag":[],"class_list":{"0":"post-172","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-control-panelscp","7":"product_cat-two-pump-cp-duplex","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product\/172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media\/175"}],"wp:attachment":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media?parent=172"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_brand?post=172"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_cat?post=172"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_tag?post=172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}