{"id":169,"date":"2019-11-11T17:30:45","date_gmt":"2019-11-11T17:30:45","guid":{"rendered":"http:\/\/maxitech.ca\/?post_type=product&#038;p=169"},"modified":"2020-01-29T15:03:47","modified_gmt":"2020-01-29T15:03:47","slug":"l922-s-duplex-pump-control-panel-for-control-protect-sewage-drainage-pump","status":"publish","type":"product","link":"https:\/\/maxitech.ca\/water\/product\/l922-s-duplex-pump-control-panel-for-control-protect-sewage-drainage-pump\/","title":{"rendered":"L922-S Duplex Pump Control Panel For Control &#038; Protect Sewage \/ Drainage Pump"},"content":{"rendered":"<div id=\"anchor_product_desc\" class=\"no_product_detaildesc\">\n<p style=\"color: tomato;\"><strong>Detailed Product Description<\/strong><\/p>\n<table class=\"details_table\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Rated Output Power:<\/th>\n<td>0.37KW-2.2KW (0.5HP-3HP)<\/td>\n<th>Rated Input Voltage:<\/th>\n<td>AC220V\/50HZ Single Phase<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>Trip Response Time Of Over Load:<\/th>\n<td>5sec-5min<\/td>\n<th>Trip Response Time Of Short Circuit:<\/th>\n<td>\uff1c0.1sec<\/td>\n<\/tr>\n<tr>\n<th>Trip Response Time Of Under \/ Over Voltage:<\/th>\n<td>\uff1c5sec<\/td>\n<th>Trip Response Time Of Dry Run:<\/th>\n<td>6sec<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>Recovery Time Of Over Load:<\/th>\n<td>30min<\/td>\n<th>Recovery Time Of Under \/ Over Voltage:<\/th>\n<td>5min<\/td>\n<\/tr>\n<tr>\n<th>Recovery Time Of Dry Run:<\/th>\n<td>30min<\/td>\n<th>Trip Voltage Of Over Voltage:<\/th>\n<td>253V<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>Trip Voltage Of Under Voltage:<\/th>\n<td>175V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"details_wrap\">\n<div class=\"clearfix\"><\/div>\n<p><strong>Intelligent <\/strong><strong>Single<\/strong><strong> Phase <\/strong><strong>Sewage<\/strong><strong> Pump Control<\/strong><strong>ler<\/strong><strong> &#8211; Auto And Manual,0.<\/strong><strong>37-2.2<\/strong><strong>KW<\/strong><\/p>\n<p><strong>Model: <\/strong><strong>L9<\/strong><strong>22-S<\/strong><\/p>\n<p style=\"color: tomato;\"><strong>Products Brief :<\/strong><\/p>\n<p>Model L922\/S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.<\/p>\n<p>Typical usage scenarios include:<br \/>\n&#8211; Houses \u3000- Flats<br \/>\n&#8211; Holidays houses \u3000- Farms<br \/>\n&#8211; Industrial plants \u3000- Construction site<\/p>\n<p><strong>Main Technical Specifications<\/strong><br \/>\nRated Input Voltage\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026AC220V \/ Single Phase<br \/>\n\u25a0 Rated Frequency\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u202650Hz-60Hz (at option)<br \/>\n\u25a0 Rated Output Power of Motor\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20260.37-2.2KW \/ 3-4KW(at option)<br \/>\n\u25a0 Short Circuit Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20260.1sec<br \/>\n\u25a0 Dry Running Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026&#8230;&#8230; 6sec<br \/>\n\u25a0 Over \/ Under Voltage Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026.5sec<br \/>\n\u25a0 Pump Stalled Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026..\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026&#8230;&#8230;0.5sec<br \/>\n\u25a0 Over Current Trip Response Time\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u20265sec-5min<br \/>\n\u25a0 Recovery Time of Over \/ Under Voltage\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026..\u2026\u2026.\u20262min<br \/>\n\u25a0 Recovery Time of Over Current\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u202630min<br \/>\n\u25a0 Recovery Time of Dry Running.\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u202630min<br \/>\n\u25a0 Over \/ Under Voltage Trip\u2026\u2026..\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026.\u2026\u00b115%<br \/>\n\u25a0 Dry Running Trip\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026.\u2026.70%<br \/>\n\u25a0 Pump Stalled Trip\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026..200%<br \/>\n\u2460 the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br \/>\n\u2461 Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is<br \/>\n253V, the Under voltage trip is 187V)<br \/>\n\u2462 Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the<br \/>\ncalibration, the dry running trip ampere is 4.2A)<br \/>\n\u2463 Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)<\/p>\n<table style=\"width: 650px; word-wrap: break-word;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 179px;\"><strong>Application<\/strong><\/td>\n<td style=\"width: 498px;\">Control &amp; protect sewage \/ drainage pump only<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Model<\/strong><\/td>\n<td style=\"width: 498px;\">L922-S<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Main technical data<\/strong><\/td>\n<td style=\"width: 498px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>.Start type<\/strong><\/td>\n<td style=\"width: 498px;\">Direct on line<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>. Qty of controll<\/strong><strong>ed<\/strong><strong> pump<\/strong><\/td>\n<td style=\"width: 498px;\">Duplex pump<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>. Rated input voltage:<\/strong><\/td>\n<td style=\"width: 498px;\">AC220V-240V Single phase<br \/>\n50HZ\/ 60HZ<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>. Rated output power:<\/strong><\/td>\n<td style=\"width: 498px;\">0.37kw-2.2kw (0.5hp-3hp)<br \/>\n3-4kw(4hp-5.5hp)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Pro<\/strong><strong>tection <\/strong><strong>function<\/strong><\/td>\n<td style=\"width: 498px;\">Over load protection<br \/>\nPump stalled protection<br \/>\nDry run protection<br \/>\nUnder voltage protection<br \/>\nRepeat start protection<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Control characteristic<\/strong><\/td>\n<td style=\"width: 498px;\">Connecting 0.5-4.5V level transmitter to replace float switch or level probe<br \/>\nDuplex pump control<br \/>\n.Main pump \/ standby pump automatically alternate<br \/>\n.Main pump \/ standby pump automatically switch against malfunction<br \/>\n.Standby pump participate running if required<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Other features<\/strong><\/td>\n<td style=\"width: 498px;\">LCD screen displaying dynamic real time depth &amp; pump running status<br \/>\nPump shaft anti-rusty<br \/>\nPump accumulative running time recording<br \/>\nPump last five faults recording displaying<br \/>\nPresenting one dry contact point (BA port)<br \/>\nPresent RS485 port<br \/>\nPresent user remote monitor<br \/>\nLCD screen locked function under Auto state<br \/>\nPush button calibration<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Main installation data<\/strong><\/td>\n<td style=\"width: 498px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 179px;\"><strong>Working temperature<\/strong><br \/>\n<strong>Working humidity<\/strong><br \/>\n<strong>Degree of protection<\/strong><br \/>\n<strong>Install position<\/strong><br \/>\n<strong>Unit dimension (L x W x H)<\/strong><\/td>\n<td style=\"width: 498px;\">-25\u2103&#8211; +55\u2103<br \/>\n20%&#8211;90%RH, no drips concreted<br \/>\nIP54<br \/>\nWall mounting<br \/>\n310 x 220x 1 20mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div><\/div>\n<div class=\"clearfix10\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-171 size-full\" src=\"http:\/\/maxitech.ca\/wp-content\/uploads\/2019\/11\/20170928155952_67961.jpg\" alt=\"\" width=\"680\" height=\"353\" srcset=\"https:\/\/maxitech.ca\/water\/wp-content\/uploads\/2019\/11\/20170928155952_67961.jpg 680w, https:\/\/maxitech.ca\/water\/wp-content\/uploads\/2019\/11\/20170928155952_67961-300x156.jpg 300w, https:\/\/maxitech.ca\/water\/wp-content\/uploads\/2019\/11\/20170928155952_67961-600x311.jpg 600w\" sizes=\"auto, (max-width: 680px) 100vw, 680px\" \/><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p class=\"txt_box\" style=\"color: tomato;\"><strong>Product Details:<\/strong><\/p>\n<table class=\"tables data\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th width=\"35%\">Certification:<\/th>\n<td>CE<\/td>\n<\/tr>\n<tr>\n<th width=\"35%\">Model Number:<\/th>\n<td>L922-S<\/td>\n<\/tr>\n<tr>\n<th nowrap=\"nowrap\" width=\"35%\">Packaging Details:<\/th>\n<td>Carton<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":2146,"template":"","meta":[],"product_brand":[],"product_cat":[15,18],"product_tag":[],"class_list":{"0":"post-169","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-control-panelscp","7":"product_cat-two-pump-cp-duplex","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product\/169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media\/2146"}],"wp:attachment":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media?parent=169"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_brand?post=169"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_cat?post=169"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_tag?post=169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}