{"id":160,"date":"2019-11-11T15:13:08","date_gmt":"2019-11-11T15:13:08","guid":{"rendered":"http:\/\/maxitech.ca\/?post_type=product&#038;p=160"},"modified":"2020-02-04T19:29:44","modified_gmt":"2020-02-04T19:29:44","slug":"1hp-20hp-sewage-pump-control-panel-with-dry-contact-point-for-building-management-system","status":"publish","type":"product","link":"https:\/\/maxitech.ca\/water\/product\/1hp-20hp-sewage-pump-control-panel-with-dry-contact-point-for-building-management-system\/","title":{"rendered":"1hp-20hp Sewage Pump Control Panel With Dry Contact Point For Building Management System"},"content":{"rendered":"<div id=\"anchor_product_desc\" class=\"no_product_detaildesc\">\n<p style=\"color: tomato;\"><strong>Detailed Product Description<\/strong><\/p>\n<table class=\"details_table\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Start Type:<\/th>\n<td>Direct On Line (DOL)<\/td>\n<th>Input Voltage:<\/th>\n<td>AC380V, 50HZ, Three Phase<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>Output Power:<\/th>\n<td>1hp-20hp<\/td>\n<th>Qty Of Controll:<\/th>\n<td>Single Pump Control<\/td>\n<\/tr>\n<tr>\n<th>Level Transmitter:<\/th>\n<td>0.5-4.5V Level Transmitter, Analog Signal Output<\/td>\n<th>Depth Value Setting &amp; Displaying:<\/th>\n<td>Press Button And LCD Displaying Dynamic Depth Value<\/td>\n<\/tr>\n<tr class=\"bg_gray\">\n<th>After-Sale Service:<\/th>\n<td>Available Modularized PCB Board<\/td>\n<th>BMS System:<\/th>\n<td>Available Dry Contact Point For BMS (Building Management System )<\/td>\n<\/tr>\n<tr>\n<th>RS 485:<\/th>\n<td>Available RS485 Port<\/td>\n<th>OEM:<\/th>\n<td>Available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"details_wrap\">\n<p><strong>SINGLE<\/strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO<\/strong><strong>R SEWAGE LIFTING <\/strong><strong>PUMP, WITH <\/strong><strong>THREE<\/strong><strong> PHASE, AC<\/strong><strong>38<\/strong><strong>0V\/50HZ<\/strong><\/p>\n<p><strong>Model <\/strong><strong>L931-S<\/strong><br \/>\nModel L931-S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.<\/p>\n<p>Typical usage scenarios include:<br \/>\n-Chemical, petroleum, pharmaceutical, mining, paper making industry<br \/>\n-Cement plant, steel plant, power plant, coal processing industry<br \/>\n-Municipal waste water treatment plants<br \/>\n-Drainage system<br \/>\n-Municipal engineering<br \/>\n-Construction site<\/p>\n<p><strong>Application<\/strong><strong> &amp; <\/strong><strong>Control characteristic:<\/strong><br \/>\nConnecting 0.5-4.5V level transmitter to replace liquid probe, float switch<br \/>\nPump start and stop according to different depth value setting<\/p>\n<p><strong>Main technical data:<\/strong><br \/>\n\u2022 Start type: Direct on line (DOL)<br \/>\n\u2022 Qty of controller pump: single pump<br \/>\n\u2022 Rated input voltage : AC380V, Three phase 50HZ\/ 60HZ<br \/>\n\u2022 Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)<\/p>\n<table style=\"width: 271px; word-wrap: break-word;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 149px;\" colspan=\"2\">Max Motor<br \/>\nOutput at 380V 3Ph<\/td>\n<td style=\"width: 123px;\">Relay<br \/>\nMax Range(A)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">HP<\/td>\n<td style=\"width: 104px;\">KW<\/td>\n<td style=\"width: 123px;\" rowspan=\"7\">12A<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">1.0<\/td>\n<td style=\"width: 104px;\">0.75<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">1.5<\/td>\n<td style=\"width: 104px;\">1.1<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">2.2<\/td>\n<td style=\"width: 104px;\">1.5<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">3.0<\/td>\n<td style=\"width: 104px;\">2.2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">5.0<\/td>\n<td style=\"width: 104px;\">3.7<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">5.5<\/td>\n<td style=\"width: 104px;\">4<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">7.5<\/td>\n<td style=\"width: 104px;\">5.5<\/td>\n<td style=\"width: 123px;\" rowspan=\"3\">25A<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">10.0<\/td>\n<td style=\"width: 104px;\">7.5<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">15.0<\/td>\n<td style=\"width: 104px;\">11<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 45px;\">20.0<\/td>\n<td style=\"width: 104px;\">15<\/td>\n<td style=\"width: 123px;\">32A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Product function <\/strong><br \/>\n\u2022 Over load protection<br \/>\n\u2022 Pump stalled protection<br \/>\n\u2022 Dry run protection with sensor free<br \/>\n\u2022 Under voltage protection<br \/>\n\u2022 Over voltage protection<br \/>\n\u2022 Rapid cycle protection<br \/>\n\u2022 Open phase protection<br \/>\n\u2022 Phase reversal protection<br \/>\n\u2022 Pump shaft anti-rust protection<br \/>\n\u2022 Three phase unbalance protection<\/p>\n<p><strong>Product feature<\/strong><br \/>\n\u2022 Pump start and stop depth value can be easily setting on the LCD screen<br \/>\n\u2022 Pump last five faults record displaying<br \/>\n\u2022 Pump accumulative running time displaying<br \/>\n\u2022 Presenting one dry contact point (BA port) for BMS system<br \/>\n\u2022 Present RS485 port (A+ \/ B\uff0d)<br \/>\n\u2022 Remote monitor available (at option)<\/p>\n<p><strong>Main installation data<\/strong><br \/>\n\u2022 Working temperature: -25\u2103&#8211; +55\u2103<br \/>\n\u2022 Working humidity: 20%&#8211;90%RH, no drips concreted<br \/>\n\u2022 Degree of protection: IP54<br \/>\n\u2022 Install position: Wall mounting<br \/>\n\u2022 Unit dimension (L x W x H): 302 x 240x 120mm<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p class=\"txt_box\" style=\"color: tomato;\"><strong>Product Details:<\/strong><\/p>\n<table class=\"tables data\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th width=\"35%\">Certification:<\/th>\n<td>CE, ISO<\/td>\n<\/tr>\n<tr>\n<th width=\"35%\">Model Number:<\/th>\n<td>L931-S<\/td>\n<\/tr>\n<tr>\n<th nowrap=\"nowrap\" width=\"35%\">Packaging Details:<\/th>\n<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":2315,"template":"","meta":[],"product_brand":[],"product_cat":[15,17],"product_tag":[],"class_list":{"0":"post-160","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-control-panelscp","7":"product_cat-single-pump-cp-simplex","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product\/160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media\/2315"}],"wp:attachment":[{"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/media?parent=160"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_brand?post=160"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_cat?post=160"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maxitech.ca\/water\/wp-json\/wp\/v2\/product_tag?post=160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}