<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Two Pump CP (Duplex) &#8211; Maxi Tech</title>
	<atom:link href="https://maxitech.ca/water/product-category/control-panelscp/two-pump-cp-duplex/feed/" rel="self" type="application/rss+xml" />
	<link>https://maxitech.ca/water</link>
	<description>Professionl Devices</description>
	<lastBuildDate>Wed, 29 Jan 2020 15:03:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>
	<item>
		<title>DOL Start Sewage Pump Control Panel 1hp-20hp Output Power , 0.5-4.5V Level Transmitter</title>
		<link>https://maxitech.ca/water/product/dol-start-sewage-pump-control-panel-1hp-20hp-output-power-0-5-4-5v-level-transmitter/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:55:31 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=178</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932-S</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Duplex Pump Control</td>
</tr>
<tr>
<th>Level Transmitter:</th>
<td>0.5-4.5V Level Transmitter, Analog Signal Output</td>
<th>Depth Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Depth Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>DUPLEX</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R SEWAGE LIFTING </strong><strong>PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L932-S</strong><br />
Eliminates the need for at least 5 water level sensor or 3 float switches: stop-level, normal- level for one pump, high-level for two pumps, overflow-alarm level. Thus significant cost-savings result from dramatically reduced purchasing and clearing of sensors or float switch.<br />
More secure because it uses level transmitter, whereas sensors or float switch often fail because of the effect of sludge.<br />
Different water levels (depth) for starting or stop the pumps can be set via LCD screen directly and real time depth value displaying;<br />
<strong>Model L93S-S</strong> is specially designed for duplex sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.</p>
<p>Typical usage scenarios include:<br />
-Chemical, petroleum, pharmaceutical, mining, paper making industry<br />
-Cement plant, steel plant, power plant, coal processing industry<br />
-Municipal waste water treatment plants<br />
-Drainage system<br />
-Municipal engineering<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V level transmitter to replace liquid probe, float switch<br />
Pump start and stop according to different depth value setting</p>
<p><strong>Duplex pump control</strong><br />
• Main pump / standby pump automatically alternate<br />
• Main pump / standby pump automatically switch against malfunction<br />
• Standby pump participate running if more flow coming</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">HP</td>
<td style="text-align: center; width: 104px;">KW</td>
<td style="text-align: center; width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.0</td>
<td style="text-align: center; width: 104px;">0.75</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.5</td>
<td style="text-align: center; width: 104px;">1.1</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">2.2</td>
<td style="text-align: center; width: 104px;">1.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">3.0</td>
<td style="text-align: center; width: 104px;">2.2</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.0</td>
<td style="text-align: center; width: 104px;">3.7</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.5</td>
<td style="text-align: center; width: 104px;">4</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">7.5</td>
<td style="text-align: center; width: 104px;">5.5</td>
<td style="text-align: center; width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">10.0</td>
<td style="text-align: center; width: 104px;">7.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">15.0</td>
<td style="text-align: center; width: 104px;">11</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">20.0</td>
<td style="text-align: center; width: 104px;">15</td>
<td style="text-align: center; width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Three phase unbalance protection<br />
• Pump shaft anti-rust protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop depth value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 120mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dual Pump Pressure Booster Pump Controller , Irrigation Pump Controller For Farms</title>
		<link>https://maxitech.ca/water/product/dual-pump-pressure-booster-pump-controller-irrigation-pump-controller-for-farms/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:44:40 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=174</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932-B</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Duplex Pump Control</td>
</tr>
<tr>
<th>Pressure Transmitter:</th>
<td>0.5-4.5V Pressure Transmitter, Analog Signal Output</td>
<th>Pressure Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Pressure Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>DUPLEX</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R PRESSURE BOOSTING</strong><strong> PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L932-B</strong><br />
Model L932-B is specially designed for duplex pressure booster pumping system, by adoption of pressure transmitter (0.5-4.5V), pump user can easily set the different pressure value and observe the dynamic pressure value in the pipeline.</p>
<p>Typical usage scenarios include:<br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V pressure transmitter to replace pressure switch<br />
Pump start and stop according to different pressure value setting</p>
<p><strong>Duplex pump control</strong><br />
• Main pump / standby pump automatically alternate<br />
• Main pump / standby pump automatically switch against malfunction<br />
• Standby pump participate running if more pressure required</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">HP</td>
<td style="text-align: center; width: 104px;">KW</td>
<td style="text-align: center; width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.0</td>
<td style="text-align: center; width: 104px;">0.75</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.5</td>
<td style="text-align: center; width: 104px;">1.1</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">2.2</td>
<td style="text-align: center; width: 104px;">1.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">3.0</td>
<td style="text-align: center; width: 104px;">2.2</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.0</td>
<td style="text-align: center; width: 104px;">3.7</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.5</td>
<td style="text-align: center; width: 104px;">4</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">7.5</td>
<td style="text-align: center; width: 104px;">5.5</td>
<td style="text-align: center; width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">10.0</td>
<td style="text-align: center; width: 104px;">7.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">15.0</td>
<td style="text-align: center; width: 104px;">11</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">20.0</td>
<td style="text-align: center; width: 104px;">15</td>
<td style="text-align: center; width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Three phase unbalance protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop pressure value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 1 20mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Duplex Sump Pump Controller , Water Pump Motor Controller Short Circuit Protection</title>
		<link>https://maxitech.ca/water/product/duplex-sump-pump-controller-water-pump-motor-controller-short-circuit-protection/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:34:26 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=172</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Phase:</th>
<td>Three Phase</td>
<th>Pump Controlled Quantity:</th>
<td>Two Pumps</td>
</tr>
<tr class="bg_gray">
<th>Enclosure Protection Grade:</th>
<td>IP54</td>
<th>Install Position:</th>
<td>Wall Mounting</td>
</tr>
<tr>
<th>Displaying ::</th>
<td>LCD Display</td>
<th>Liquid Level Transfer Distance:</th>
<td>≤1000m</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>Digital Three Phase Water Pump Control Panel &#8211; Auto And Manual,00.75-15KW ,With One Button Calibration.</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p><strong>L932</strong> is applied for automatic liquid level control / pressure control and effective protection for duplex pumps of with AC380V, 50hz, single phase output power 0.75KW-15KW (1HP-20HP),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.<br />
<strong>Model L932</strong> has many operation modes by adopting different electric installations. An important feature that makes the difference between Model L932 and common On/Off pump control box is the probe / sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe / sensor in the well.<br />
<strong>Model L932</strong> is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.</p>
<p><strong>Main Technical Specifications</strong><br />
■Rated Input Voltage…………………………………………………AC380V / Three Phase<br />
■ Rated Frequency…………………………………………50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor…………………0.75-4KW / 5.5-11KW/15KW(at option)<br />
■ Open Phase Trip Response Time…….……………………2sec<br />
■ Short Circuit Trip Response Time……………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………5sec<br />
■ Pump Stalled Trip Response Time……………………..………0.5sec<br />
■ Over Current Trip Response Time……………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage……………………………………2min<br />
■ Recovery Time of Over Current…………………………………………30min<br />
■ Recovery Time of Dry Running.………………………………………………30min<br />
■ Over / Under Voltage Trip……..……………………………….………………±15%<br />
■ Dry Running Trip……………………………………………….70%<br />
■ Pump Stalled Trip………………………………………….……………………200%</p>
<p>① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 182px;"><strong>Model</strong></td>
<td style="width: 523px;">L932</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main technical data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Start type</strong></td>
<td style="width: 523px;">Direct on line</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Qty of controlled pump</strong></td>
<td style="width: 523px;">Two pumps</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated input voltage:</strong></td>
<td style="width: 523px;">AC380V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated output power:</strong></td>
<td style="width: 523px;">0.75KW-15KW (1HP-20HP)</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Capacitor:</strong></td>
<td style="width: 523px;">N/M</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Protection Offered:</strong></td>
<td style="width: 523px;">Dry run<br />
Over load<br />
Transient surge<br />
Under voltage<br />
Over voltage<br />
Open phase<br />
Pump shaft rust protection<br />
Pump stalled<br />
Short circuit<br />
Over temp<br />
Three phase unbalance<br />
Phase reversal<br />
Repeated start</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Application &amp; </strong><strong>Control chara</strong><strong>c</strong><strong>teristic</strong></td>
<td style="width: 523px;">Control and protect universal pump<br />
Using water level sensor or float switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Other features</strong></td>
<td style="width: 523px;">Push button calibration<br />
Memory function when power off &amp; recovery<strong>Interactive LCD Screen</strong></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main installation data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 523px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP22<br />
Wall mounting<br />
1 70× 1 55× 8.5mm</td>
</tr>
</tbody>
</table>
<div class="clearfix10"></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>L922-S Duplex Pump Control Panel For Control &#038; Protect Sewage / Drainage Pump</title>
		<link>https://maxitech.ca/water/product/l922-s-duplex-pump-control-panel-for-control-protect-sewage-drainage-pump/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:30:45 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=169</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922-S</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Rated Output Power:</th>
<td>0.37KW-2.2KW (0.5HP-3HP)</td>
<th>Rated Input Voltage:</th>
<td>AC220V/50HZ Single Phase</td>
</tr>
<tr class="bg_gray">
<th>Trip Response Time Of Over Load:</th>
<td>5sec-5min</td>
<th>Trip Response Time Of Short Circuit:</th>
<td>＜0.1sec</td>
</tr>
<tr>
<th>Trip Response Time Of Under / Over Voltage:</th>
<td>＜5sec</td>
<th>Trip Response Time Of Dry Run:</th>
<td>6sec</td>
</tr>
<tr class="bg_gray">
<th>Recovery Time Of Over Load:</th>
<td>30min</td>
<th>Recovery Time Of Under / Over Voltage:</th>
<td>5min</td>
</tr>
<tr>
<th>Recovery Time Of Dry Run:</th>
<td>30min</td>
<th>Trip Voltage Of Over Voltage:</th>
<td>253V</td>
</tr>
<tr class="bg_gray">
<th>Trip Voltage Of Under Voltage:</th>
<td>175V</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>Intelligent </strong><strong>Single</strong><strong> Phase </strong><strong>Sewage</strong><strong> Pump Control</strong><strong>ler</strong><strong> &#8211; Auto And Manual,0.</strong><strong>37-2.2</strong><strong>KW</strong></p>
<p><strong>Model: </strong><strong>L9</strong><strong>22-S</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p>Model L922/S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.</p>
<p>Typical usage scenarios include:<br />
&#8211; Houses 　- Flats<br />
&#8211; Holidays houses 　- Farms<br />
&#8211; Industrial plants 　- Construction site</p>
<p><strong>Main Technical Specifications</strong><br />
Rated Input Voltage…………………………………………………AC220V / Single Phase<br />
■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor……………………………0.37-2.2KW / 3-4KW(at option)<br />
■ Short Circuit Trip Response Time……………………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………&#8230;&#8230; 6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………….….5sec<br />
■ Pump Stalled Trip Response Time……………………..…………………………&#8230;&#8230;0.5sec<br />
■ Over Current Trip Response Time………………………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage………………………………………..…….…2min<br />
■ Recovery Time of Over Current…………………………………………………….…30min<br />
■ Recovery Time of Dry Running.………………………………………………….…30min<br />
■ Over / Under Voltage Trip……..……………………………….………………….….…±15%<br />
■ Dry Running Trip……………………………………………….………………….…….….70%<br />
■ Pump Stalled Trip………………………………………….……………………………..200%<br />
① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is<br />
253V, the Under voltage trip is 187V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the<br />
calibration, the dry running trip ampere is 4.2A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 179px;"><strong>Application</strong></td>
<td style="width: 498px;">Control &amp; protect sewage / drainage pump only</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Model</strong></td>
<td style="width: 498px;">L922-S</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Main technical data</strong></td>
<td style="width: 498px;"></td>
</tr>
<tr>
<td style="width: 179px;"><strong>.Start type</strong></td>
<td style="width: 498px;">Direct on line</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 498px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 498px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Rated output power:</strong></td>
<td style="width: 498px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 498px;">Over load protection<br />
Pump stalled protection<br />
Dry run protection<br />
Under voltage protection<br />
Repeat start protection</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Control characteristic</strong></td>
<td style="width: 498px;">Connecting 0.5-4.5V level transmitter to replace float switch or level probe<br />
Duplex pump control<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Other features</strong></td>
<td style="width: 498px;">LCD screen displaying dynamic real time depth &amp; pump running status<br />
Pump shaft anti-rusty<br />
Pump accumulative running time recording<br />
Pump last five faults recording displaying<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor<br />
LCD screen locked function under Auto state<br />
Push button calibration</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Main installation data</strong></td>
<td style="width: 498px;"></td>
</tr>
<tr>
<td style="width: 179px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 498px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 1 20mm</td>
</tr>
</tbody>
</table>
<div></div>
<div class="clearfix10"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-171 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170928155952_67961.jpg" alt="" width="680" height="353" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961.jpg 680w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961-300x156.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961-600x311.jpg 600w" sizes="(max-width: 680px) 100vw, 680px" /></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>0.37-2.2KW Booster Pump Controller With Pressure Transmitter 0.5-4.5V</title>
		<link>https://maxitech.ca/water/product/0-37-2-2kw-booster-pump-controller-with-pressure-transmitter-0-5-4-5v/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:19:57 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=167</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922-B</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Phase:</th>
<td>Single Phase</td>
<th>Pump Controlled Quantity:</th>
<td>One Pump</td>
</tr>
<tr class="bg_gray">
<th>Enclosure Protection Grade:</th>
<td>IP54</td>
<th>Install Position:</th>
<td>Wall Mounting</td>
</tr>
<tr>
<th>Displaying ::</th>
<td>LCD Display</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>ntelligent </strong><strong>Single</strong><strong> Phase</strong><strong> Duplex Booster</strong><strong> Pump Control</strong><strong>ler</strong><strong>&#8211; Auto And Manual,0.</strong><strong>37-2.2</strong><strong>KW</strong></p>
<p><strong>Model: </strong><strong>L9</strong><strong>22-B</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p>Model L922-B is specially designed for pressure booster pumping system, by adopting pressure transmitter (0.5-4.5V), pump user can easily set the different pressure value and observe the dynamic pressure value in the pipeline.</p>
<p>Typical usage scenarios include:<br />
&#8211; Houses &#8211; Flats<br />
&#8211; Holidays houses &#8211; Farms<br />
&#8211; Water supply from wells &#8211; Industrial plants</p>
<p><strong>Main Technical Specifications</strong><br />
Rated Input Voltage…………………………………………………AC220V / Single Phase<br />
■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor……………………………0.37-2.2KW / 3-4KW(at option)<br />
■ Short Circuit Trip Response Time……………………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………&#8230;&#8230; 6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………….….5sec<br />
■ Pump Stalled Trip Response Time……………………..…………………………&#8230;&#8230;0.5sec<br />
■ Over Current Trip Response Time………………………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage………………………………………..…….…2min<br />
■ Recovery Time of Over Current…………………………………………………….…30min<br />
■ Recovery Time of Dry Running.………………………………………………….…30min<br />
■ Over / Under Voltage Trip……..……………………………….………………….….…±15%<br />
■ Dry Running Trip……………………………………………….………………….…….….70%<br />
■ Pump Stalled Trip………………………………………….……………………………..200%</p>
<p>①the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is<br />
253V, the Under voltage trip is 187V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the<br />
calibration, the dry running trip ampere is 4.2A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 181px;"><strong>Application</strong></td>
<td style="width: 489px;">Control &amp; protect booster pump only</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Model</strong></td>
<td style="width: 489px;">L922-B</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Main technical data</strong></td>
<td style="width: 489px;"></td>
</tr>
<tr>
<td style="width: 181px;"><strong>.Start type</strong></td>
<td style="width: 489px;">Direct on line</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 489px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 489px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Rated output power:</strong></td>
<td style="width: 489px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 489px;">Over load protection<br />
Pump stalled protection<br />
Dry run protection<br />
Under voltage protection<br />
Over voltage protection<br />
Repeat start protection</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Control characteristic</strong></td>
<td style="width: 489px;">Connecting 0.5-4.5V pressure transmitter to replace pressure switch<br />
Duplex pump control<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Other features</strong></td>
<td style="width: 489px;">LCD screen displaying dynamic real time pressure value &amp; pump running status<br />
Pump accumulative running time recording<br />
Pump last five faults record displaying<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor<br />
LCD screen locked function under Auto state<br />
Push button calibration</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Main installation data</strong></td>
<td style="width: 489px;"></td>
</tr>
<tr>
<td style="width: 181px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 489px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 1 20mm</td>
</tr>
</tbody>
</table>
<div></div>
<div class="clearfix10"><img decoding="async" class="aligncenter wp-image-168 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170925143150_18286.jpg" alt="" width="679" height="372" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286.jpg 679w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286-300x164.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286-600x329.jpg 600w" sizes="(max-width: 679px) 100vw, 679px" /></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>L922 Duplex Pump Controller , Single Phase Pump Controller Under Voltage Protection</title>
		<link>https://maxitech.ca/water/product/l922-duplex-pump-controller-single-phase-pump-controller-under-voltage-protection/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:02:07 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=164</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Paper Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Output Power:</th>
<td>0.37-2.2KW</td>
<th>Input Volatge:</th>
<td>AC220V</td>
</tr>
<tr class="bg_gray">
<th>Phase:</th>
<td>Single Phase</td>
<th>Frequency:</th>
<td>50Hz</td>
</tr>
<tr>
<th>Start Type:</th>
<td>DOL Start</td>
<th>Protection Grade:</th>
<td>IP54</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>Full Automatic Pump Control Panel , Start Type DOL , Single Phase</strong></p>
<p><img decoding="async" class="aligncenter wp-image-165 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170913155446_43114.jpg" alt="" width="680" height="163" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114.jpg 680w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114-300x72.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114-600x144.jpg 600w" sizes="(max-width: 680px) 100vw, 680px" /></p>
<p><strong>Product function</strong><strong> / features :</strong></p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 189px;"><strong>Model</strong></td>
<td style="width: 455px;">L922</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Main technical data</strong></td>
<td style="width: 455px;"></td>
</tr>
<tr>
<td style="width: 189px;"><strong>.Start type</strong></td>
<td style="width: 455px;">Direct on line</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 455px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 455px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Rated output power:</strong></td>
<td style="width: 455px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 455px;">Over load protection<br />
Pump stalled protection<br />
Dry run protectionwith sensor free<br />
Under voltage protection<br />
Over voltage protection<br />
Rapid cycle protection</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Application </strong></td>
<td style="width: 455px;">Control and protect universal pump<br />
Using water level sensor ,float switch or pressure switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Control characteristic</strong></td>
<td style="width: 455px;">Duplex pump control<br />
Build in function switch for water transfer ,booster and sewage lifting (drainage)<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Other features</strong></td>
<td style="width: 455px;">Pump last five faults record displaying<br />
Pump accumulative running time displaying<br />
Pump shaft anti-rust<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Main installation data</strong></td>
<td style="width: 455px;"></td>
</tr>
<tr>
<td style="width: 189px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 455px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 120mm</td>
</tr>
</tbody>
</table>
<p><strong>Our Service: </strong><br />
1.Payment Terms :we can accept payment by T/T ,L/C,PAYPAL<br />
2.Delivery Terms :by sea ,by air ,DHL,TNT,UPS,FEDEX</p>
<p><strong>Application :</strong><br />
Control and protect universal pump<br />
Using water level sensor or float switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</p>
<p><strong>Typical usage scenarios include:</strong><br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Waste water tank / Sewage sink</p>
<p><strong>Main installation data:</strong><br />
Working temperature: -25 &#8212; +25 centigrade<br />
Working humidity :20% &#8212; 90% RH, no drips concreted<br />
Install position :Wall mounting<br />
Degree of protection :IP54</p>