<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Control Panels(CP) &#8211; Maxi Tech</title>
	<atom:link href="https://maxitech.ca/water/product-category/control-panelscp/feed/" rel="self" type="application/rss+xml" />
	<link>https://maxitech.ca/water</link>
	<description>Professionl Devices</description>
	<lastBuildDate>Tue, 04 Feb 2020 19:36:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>
	<item>
		<title>DOL Start Sewage Pump Control Panel 1hp-20hp Output Power , 0.5-4.5V Level Transmitter</title>
		<link>https://maxitech.ca/water/product/dol-start-sewage-pump-control-panel-1hp-20hp-output-power-0-5-4-5v-level-transmitter/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:55:31 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=178</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932-S</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Duplex Pump Control</td>
</tr>
<tr>
<th>Level Transmitter:</th>
<td>0.5-4.5V Level Transmitter, Analog Signal Output</td>
<th>Depth Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Depth Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>DUPLEX</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R SEWAGE LIFTING </strong><strong>PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L932-S</strong><br />
Eliminates the need for at least 5 water level sensor or 3 float switches: stop-level, normal- level for one pump, high-level for two pumps, overflow-alarm level. Thus significant cost-savings result from dramatically reduced purchasing and clearing of sensors or float switch.<br />
More secure because it uses level transmitter, whereas sensors or float switch often fail because of the effect of sludge.<br />
Different water levels (depth) for starting or stop the pumps can be set via LCD screen directly and real time depth value displaying;<br />
<strong>Model L93S-S</strong> is specially designed for duplex sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.</p>
<p>Typical usage scenarios include:<br />
-Chemical, petroleum, pharmaceutical, mining, paper making industry<br />
-Cement plant, steel plant, power plant, coal processing industry<br />
-Municipal waste water treatment plants<br />
-Drainage system<br />
-Municipal engineering<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V level transmitter to replace liquid probe, float switch<br />
Pump start and stop according to different depth value setting</p>
<p><strong>Duplex pump control</strong><br />
• Main pump / standby pump automatically alternate<br />
• Main pump / standby pump automatically switch against malfunction<br />
• Standby pump participate running if more flow coming</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">HP</td>
<td style="text-align: center; width: 104px;">KW</td>
<td style="text-align: center; width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.0</td>
<td style="text-align: center; width: 104px;">0.75</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.5</td>
<td style="text-align: center; width: 104px;">1.1</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">2.2</td>
<td style="text-align: center; width: 104px;">1.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">3.0</td>
<td style="text-align: center; width: 104px;">2.2</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.0</td>
<td style="text-align: center; width: 104px;">3.7</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.5</td>
<td style="text-align: center; width: 104px;">4</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">7.5</td>
<td style="text-align: center; width: 104px;">5.5</td>
<td style="text-align: center; width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">10.0</td>
<td style="text-align: center; width: 104px;">7.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">15.0</td>
<td style="text-align: center; width: 104px;">11</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">20.0</td>
<td style="text-align: center; width: 104px;">15</td>
<td style="text-align: center; width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Three phase unbalance protection<br />
• Pump shaft anti-rust protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop depth value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 120mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dual Pump Pressure Booster Pump Controller , Irrigation Pump Controller For Farms</title>
		<link>https://maxitech.ca/water/product/dual-pump-pressure-booster-pump-controller-irrigation-pump-controller-for-farms/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:44:40 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=174</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932-B</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Duplex Pump Control</td>
</tr>
<tr>
<th>Pressure Transmitter:</th>
<td>0.5-4.5V Pressure Transmitter, Analog Signal Output</td>
<th>Pressure Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Pressure Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>DUPLEX</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R PRESSURE BOOSTING</strong><strong> PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L932-B</strong><br />
Model L932-B is specially designed for duplex pressure booster pumping system, by adoption of pressure transmitter (0.5-4.5V), pump user can easily set the different pressure value and observe the dynamic pressure value in the pipeline.</p>
<p>Typical usage scenarios include:<br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V pressure transmitter to replace pressure switch<br />
Pump start and stop according to different pressure value setting</p>
<p><strong>Duplex pump control</strong><br />
• Main pump / standby pump automatically alternate<br />
• Main pump / standby pump automatically switch against malfunction<br />
• Standby pump participate running if more pressure required</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">HP</td>
<td style="text-align: center; width: 104px;">KW</td>
<td style="text-align: center; width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.0</td>
<td style="text-align: center; width: 104px;">0.75</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.5</td>
<td style="text-align: center; width: 104px;">1.1</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">2.2</td>
<td style="text-align: center; width: 104px;">1.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">3.0</td>
<td style="text-align: center; width: 104px;">2.2</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.0</td>
<td style="text-align: center; width: 104px;">3.7</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.5</td>
<td style="text-align: center; width: 104px;">4</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">7.5</td>
<td style="text-align: center; width: 104px;">5.5</td>
<td style="text-align: center; width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">10.0</td>
<td style="text-align: center; width: 104px;">7.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">15.0</td>
<td style="text-align: center; width: 104px;">11</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">20.0</td>
<td style="text-align: center; width: 104px;">15</td>
<td style="text-align: center; width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Three phase unbalance protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop pressure value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 1 20mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Duplex Sump Pump Controller , Water Pump Motor Controller Short Circuit Protection</title>
		<link>https://maxitech.ca/water/product/duplex-sump-pump-controller-water-pump-motor-controller-short-circuit-protection/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 18:34:26 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=172</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L932</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Phase:</th>
<td>Three Phase</td>
<th>Pump Controlled Quantity:</th>
<td>Two Pumps</td>
</tr>
<tr class="bg_gray">
<th>Enclosure Protection Grade:</th>
<td>IP54</td>
<th>Install Position:</th>
<td>Wall Mounting</td>
</tr>
<tr>
<th>Displaying ::</th>
<td>LCD Display</td>
<th>Liquid Level Transfer Distance:</th>
<td>≤1000m</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>Digital Three Phase Water Pump Control Panel &#8211; Auto And Manual,00.75-15KW ,With One Button Calibration.</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p><strong>L932</strong> is applied for automatic liquid level control / pressure control and effective protection for duplex pumps of with AC380V, 50hz, single phase output power 0.75KW-15KW (1HP-20HP),direct start, including stainless steel or cast iron submersible pump,centrifugal pump, sewage pump etc.<br />
<strong>Model L932</strong> has many operation modes by adopting different electric installations. An important feature that makes the difference between Model L932 and common On/Off pump control box is the probe / sensor free in the well. Our special design makes it a very reliable and sensitive Protection against pump dry run without installation probe / sensor in the well.<br />
<strong>Model L932</strong> is useful in all cases we need to control and protect single pump managing its turn-on and turn off by different electric installations.</p>
<p><strong>Main Technical Specifications</strong><br />
■Rated Input Voltage…………………………………………………AC380V / Three Phase<br />
■ Rated Frequency…………………………………………50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor…………………0.75-4KW / 5.5-11KW/15KW(at option)<br />
■ Open Phase Trip Response Time…….……………………2sec<br />
■ Short Circuit Trip Response Time……………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………5sec<br />
■ Pump Stalled Trip Response Time……………………..………0.5sec<br />
■ Over Current Trip Response Time……………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage……………………………………2min<br />
■ Recovery Time of Over Current…………………………………………30min<br />
■ Recovery Time of Dry Running.………………………………………………30min<br />
■ Over / Under Voltage Trip……..……………………………….………………±15%<br />
■ Dry Running Trip……………………………………………….70%<br />
■ Pump Stalled Trip………………………………………….……………………200%</p>
<p>① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 182px;"><strong>Model</strong></td>
<td style="width: 523px;">L932</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main technical data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Start type</strong></td>
<td style="width: 523px;">Direct on line</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Qty of controlled pump</strong></td>
<td style="width: 523px;">Two pumps</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated input voltage:</strong></td>
<td style="width: 523px;">AC380V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated output power:</strong></td>
<td style="width: 523px;">0.75KW-15KW (1HP-20HP)</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Capacitor:</strong></td>
<td style="width: 523px;">N/M</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Protection Offered:</strong></td>
<td style="width: 523px;">Dry run<br />
Over load<br />
Transient surge<br />
Under voltage<br />
Over voltage<br />
Open phase<br />
Pump shaft rust protection<br />
Pump stalled<br />
Short circuit<br />
Over temp<br />
Three phase unbalance<br />
Phase reversal<br />
Repeated start</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Application &amp; </strong><strong>Control chara</strong><strong>c</strong><strong>teristic</strong></td>
<td style="width: 523px;">Control and protect universal pump<br />
Using water level sensor or float switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Other features</strong></td>
<td style="width: 523px;">Push button calibration<br />
Memory function when power off &amp; recovery<strong>Interactive LCD Screen</strong></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main installation data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 523px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP22<br />
Wall mounting<br />
1 70× 1 55× 8.5mm</td>
</tr>
</tbody>
</table>
<div class="clearfix10"></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>L922-S Duplex Pump Control Panel For Control &#038; Protect Sewage / Drainage Pump</title>
		<link>https://maxitech.ca/water/product/l922-s-duplex-pump-control-panel-for-control-protect-sewage-drainage-pump/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:30:45 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=169</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922-S</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Rated Output Power:</th>
<td>0.37KW-2.2KW (0.5HP-3HP)</td>
<th>Rated Input Voltage:</th>
<td>AC220V/50HZ Single Phase</td>
</tr>
<tr class="bg_gray">
<th>Trip Response Time Of Over Load:</th>
<td>5sec-5min</td>
<th>Trip Response Time Of Short Circuit:</th>
<td>＜0.1sec</td>
</tr>
<tr>
<th>Trip Response Time Of Under / Over Voltage:</th>
<td>＜5sec</td>
<th>Trip Response Time Of Dry Run:</th>
<td>6sec</td>
</tr>
<tr class="bg_gray">
<th>Recovery Time Of Over Load:</th>
<td>30min</td>
<th>Recovery Time Of Under / Over Voltage:</th>
<td>5min</td>
</tr>
<tr>
<th>Recovery Time Of Dry Run:</th>
<td>30min</td>
<th>Trip Voltage Of Over Voltage:</th>
<td>253V</td>
</tr>
<tr class="bg_gray">
<th>Trip Voltage Of Under Voltage:</th>
<td>175V</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>Intelligent </strong><strong>Single</strong><strong> Phase </strong><strong>Sewage</strong><strong> Pump Control</strong><strong>ler</strong><strong> &#8211; Auto And Manual,0.</strong><strong>37-2.2</strong><strong>KW</strong></p>
<p><strong>Model: </strong><strong>L9</strong><strong>22-S</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p>Model L922/S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.</p>
<p>Typical usage scenarios include:<br />
&#8211; Houses 　- Flats<br />
&#8211; Holidays houses 　- Farms<br />
&#8211; Industrial plants 　- Construction site</p>
<p><strong>Main Technical Specifications</strong><br />
Rated Input Voltage…………………………………………………AC220V / Single Phase<br />
■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor……………………………0.37-2.2KW / 3-4KW(at option)<br />
■ Short Circuit Trip Response Time……………………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………&#8230;&#8230; 6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………….….5sec<br />
■ Pump Stalled Trip Response Time……………………..…………………………&#8230;&#8230;0.5sec<br />
■ Over Current Trip Response Time………………………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage………………………………………..…….…2min<br />
■ Recovery Time of Over Current…………………………………………………….…30min<br />
■ Recovery Time of Dry Running.………………………………………………….…30min<br />
■ Over / Under Voltage Trip……..……………………………….………………….….…±15%<br />
■ Dry Running Trip……………………………………………….………………….…….….70%<br />
■ Pump Stalled Trip………………………………………….……………………………..200%<br />
① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is<br />
253V, the Under voltage trip is 187V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the<br />
calibration, the dry running trip ampere is 4.2A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 179px;"><strong>Application</strong></td>
<td style="width: 498px;">Control &amp; protect sewage / drainage pump only</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Model</strong></td>
<td style="width: 498px;">L922-S</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Main technical data</strong></td>
<td style="width: 498px;"></td>
</tr>
<tr>
<td style="width: 179px;"><strong>.Start type</strong></td>
<td style="width: 498px;">Direct on line</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 498px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 498px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 179px;"><strong>. Rated output power:</strong></td>
<td style="width: 498px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 498px;">Over load protection<br />
Pump stalled protection<br />
Dry run protection<br />
Under voltage protection<br />
Repeat start protection</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Control characteristic</strong></td>
<td style="width: 498px;">Connecting 0.5-4.5V level transmitter to replace float switch or level probe<br />
Duplex pump control<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Other features</strong></td>
<td style="width: 498px;">LCD screen displaying dynamic real time depth &amp; pump running status<br />
Pump shaft anti-rusty<br />
Pump accumulative running time recording<br />
Pump last five faults recording displaying<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor<br />
LCD screen locked function under Auto state<br />
Push button calibration</td>
</tr>
<tr>
<td style="width: 179px;"><strong>Main installation data</strong></td>
<td style="width: 498px;"></td>
</tr>
<tr>
<td style="width: 179px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 498px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 1 20mm</td>
</tr>
</tbody>
</table>
<div></div>
<div class="clearfix10"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-171 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170928155952_67961.jpg" alt="" width="680" height="353" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961.jpg 680w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961-300x156.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170928155952_67961-600x311.jpg 600w" sizes="(max-width: 680px) 100vw, 680px" /></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>0.37-2.2KW Booster Pump Controller With Pressure Transmitter 0.5-4.5V</title>
		<link>https://maxitech.ca/water/product/0-37-2-2kw-booster-pump-controller-with-pressure-transmitter-0-5-4-5v/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:19:57 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=167</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922-B</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Phase:</th>
<td>Single Phase</td>
<th>Pump Controlled Quantity:</th>
<td>One Pump</td>
</tr>
<tr class="bg_gray">
<th>Enclosure Protection Grade:</th>
<td>IP54</td>
<th>Install Position:</th>
<td>Wall Mounting</td>
</tr>
<tr>
<th>Displaying ::</th>
<td>LCD Display</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>ntelligent </strong><strong>Single</strong><strong> Phase</strong><strong> Duplex Booster</strong><strong> Pump Control</strong><strong>ler</strong><strong>&#8211; Auto And Manual,0.</strong><strong>37-2.2</strong><strong>KW</strong></p>
<p><strong>Model: </strong><strong>L9</strong><strong>22-B</strong></p>
<p style="color: tomato;"><strong>Products Brief :</strong></p>
<p>Model L922-B is specially designed for pressure booster pumping system, by adopting pressure transmitter (0.5-4.5V), pump user can easily set the different pressure value and observe the dynamic pressure value in the pipeline.</p>
<p>Typical usage scenarios include:<br />
&#8211; Houses &#8211; Flats<br />
&#8211; Holidays houses &#8211; Farms<br />
&#8211; Water supply from wells &#8211; Industrial plants</p>
<p><strong>Main Technical Specifications</strong><br />
Rated Input Voltage…………………………………………………AC220V / Single Phase<br />
■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)<br />
■ Rated Output Power of Motor……………………………0.37-2.2KW / 3-4KW(at option)<br />
■ Short Circuit Trip Response Time……………………………………………………0.1sec<br />
■ Dry Running Trip Response Time………………………………………………&#8230;&#8230; 6sec<br />
■ Over / Under Voltage Trip Response Time……………………………………….….5sec<br />
■ Pump Stalled Trip Response Time……………………..…………………………&#8230;&#8230;0.5sec<br />
■ Over Current Trip Response Time………………………………………………5sec-5min<br />
■ Recovery Time of Over / Under Voltage………………………………………..…….…2min<br />
■ Recovery Time of Over Current…………………………………………………….…30min<br />
■ Recovery Time of Dry Running.………………………………………………….…30min<br />
■ Over / Under Voltage Trip……..……………………………….………………….….…±15%<br />
■ Dry Running Trip……………………………………………….………………….…….….70%<br />
■ Pump Stalled Trip………………………………………….……………………………..200%</p>
<p>①the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)<br />
② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is<br />
253V, the Under voltage trip is 187V)<br />
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the<br />
calibration, the dry running trip ampere is 4.2A)<br />
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 181px;"><strong>Application</strong></td>
<td style="width: 489px;">Control &amp; protect booster pump only</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Model</strong></td>
<td style="width: 489px;">L922-B</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Main technical data</strong></td>
<td style="width: 489px;"></td>
</tr>
<tr>
<td style="width: 181px;"><strong>.Start type</strong></td>
<td style="width: 489px;">Direct on line</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 489px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 489px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 181px;"><strong>. Rated output power:</strong></td>
<td style="width: 489px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 489px;">Over load protection<br />
Pump stalled protection<br />
Dry run protection<br />
Under voltage protection<br />
Over voltage protection<br />
Repeat start protection</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Control characteristic</strong></td>
<td style="width: 489px;">Connecting 0.5-4.5V pressure transmitter to replace pressure switch<br />
Duplex pump control<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Other features</strong></td>
<td style="width: 489px;">LCD screen displaying dynamic real time pressure value &amp; pump running status<br />
Pump accumulative running time recording<br />
Pump last five faults record displaying<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor<br />
LCD screen locked function under Auto state<br />
Push button calibration</td>
</tr>
<tr>
<td style="width: 181px;"><strong>Main installation data</strong></td>
<td style="width: 489px;"></td>
</tr>
<tr>
<td style="width: 181px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 489px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 1 20mm</td>
</tr>
</tbody>
</table>
<div></div>
<div class="clearfix10"><img decoding="async" class="aligncenter wp-image-168 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170925143150_18286.jpg" alt="" width="679" height="372" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286.jpg 679w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286-300x164.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170925143150_18286-600x329.jpg 600w" sizes="(max-width: 679px) 100vw, 679px" /></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>L922 Duplex Pump Controller , Single Phase Pump Controller Under Voltage Protection</title>
		<link>https://maxitech.ca/water/product/l922-duplex-pump-controller-single-phase-pump-controller-under-voltage-protection/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 17:02:07 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=164</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L922</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Paper Carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Output Power:</th>
<td>0.37-2.2KW</td>
<th>Input Volatge:</th>
<td>AC220V</td>
</tr>
<tr class="bg_gray">
<th>Phase:</th>
<td>Single Phase</td>
<th>Frequency:</th>
<td>50Hz</td>
</tr>
<tr>
<th>Start Type:</th>
<td>DOL Start</td>
<th>Protection Grade:</th>
<td>IP54</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>Full Automatic Pump Control Panel , Start Type DOL , Single Phase</strong></p>
<p><img decoding="async" class="aligncenter wp-image-165 size-full" src="http://maxitech.ca/wp-content/uploads/2019/11/20170913155446_43114.jpg" alt="" width="680" height="163" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114.jpg 680w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114-300x72.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913155446_43114-600x144.jpg 600w" sizes="(max-width: 680px) 100vw, 680px" /></p>
<p><strong>Product function</strong><strong> / features :</strong></p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 189px;"><strong>Model</strong></td>
<td style="width: 455px;">L922</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Main technical data</strong></td>
<td style="width: 455px;"></td>
</tr>
<tr>
<td style="width: 189px;"><strong>.Start type</strong></td>
<td style="width: 455px;">Direct on line</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Qty of controll</strong><strong>ed</strong><strong> pump</strong></td>
<td style="width: 455px;">Duplex pump</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Rated input voltage:</strong></td>
<td style="width: 455px;">AC220V-240V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 189px;"><strong>. Rated output power:</strong></td>
<td style="width: 455px;">0.37kw-2.2kw (0.5hp-3hp)<br />
3-4kw(4hp-5.5hp)</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Pro</strong><strong>tection </strong><strong>function</strong></td>
<td style="width: 455px;">Over load protection<br />
Pump stalled protection<br />
Dry run protectionwith sensor free<br />
Under voltage protection<br />
Over voltage protection<br />
Rapid cycle protection</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Application </strong></td>
<td style="width: 455px;">Control and protect universal pump<br />
Using water level sensor ,float switch or pressure switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Control characteristic</strong></td>
<td style="width: 455px;">Duplex pump control<br />
Build in function switch for water transfer ,booster and sewage lifting (drainage)<br />
.Main pump / standby pump automatically alternate<br />
.Main pump / standby pump automatically switch against malfunction<br />
.Standby pump participate running if required</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Other features</strong></td>
<td style="width: 455px;">Pump last five faults record displaying<br />
Pump accumulative running time displaying<br />
Pump shaft anti-rust<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor</td>
</tr>
<tr>
<td style="width: 189px;"><strong>Main installation data</strong></td>
<td style="width: 455px;"></td>
</tr>
<tr>
<td style="width: 189px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 455px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
310 x 220x 120mm</td>
</tr>
</tbody>
</table>
<p><strong>Our Service: </strong><br />
1.Payment Terms :we can accept payment by T/T ,L/C,PAYPAL<br />
2.Delivery Terms :by sea ,by air ,DHL,TNT,UPS,FEDEX</p>
<p><strong>Application :</strong><br />
Control and protect universal pump<br />
Using water level sensor or float switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</p>
<p><strong>Typical usage scenarios include:</strong><br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Waste water tank / Sewage sink</p>
<p><strong>Main installation data:</strong><br />
Working temperature: -25 &#8212; +25 centigrade<br />
Working humidity :20% &#8212; 90% RH, no drips concreted<br />
Install position :Wall mounting<br />
Degree of protection :IP54</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rainwater Reuse Booster Pump Controller , 1hp-20hp Auto Water Pump Controller</title>
		<link>https://maxitech.ca/water/product/rainwater-reuse-booster-pump-controller-1hp-20hp-auto-water-pump-controller/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 15:44:35 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=162</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L931-B</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Single Pump Control</td>
</tr>
<tr>
<th>Pressure Transmitter:</th>
<td>0.5-4.5V Pressure Transmitter, Analog Signal Output</td>
<th>Pressure Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Pressure Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>SINGLE</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R PRESSURE BOOSTING</strong><strong> PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L931-B</strong><br />
Model L931-B is specially designed for pressure booster pumping system, by adoption of pressure transmitter (0.5-4.5V), pump user can easily set the different pressure value and observe the dynamic pressure value in the pipeline.</p>
<p>Typical usage scenarios include:<br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V pressure transmitter to replace pressure switch<br />
Pump start and stop according to different pressure value setting</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">HP</td>
<td style="text-align: center; width: 104px;">KW</td>
<td style="text-align: center; width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.0</td>
<td style="text-align: center; width: 104px;">0.75</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">1.5</td>
<td style="text-align: center; width: 104px;">1.1</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">2.2</td>
<td style="text-align: center; width: 104px;">1.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">3.0</td>
<td style="text-align: center; width: 104px;">2.2</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.0</td>
<td style="text-align: center; width: 104px;">3.7</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">5.5</td>
<td style="text-align: center; width: 104px;">4</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">7.5</td>
<td style="text-align: center; width: 104px;">5.5</td>
<td style="text-align: center; width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">10.0</td>
<td style="text-align: center; width: 104px;">7.5</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">15.0</td>
<td style="text-align: center; width: 104px;">11</td>
</tr>
<tr>
<td style="text-align: center; width: 45px;">20.0</td>
<td style="text-align: center; width: 104px;">15</td>
<td style="text-align: center; width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Three phase unbalance protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop pressure value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 1 20mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>1hp-20hp Sewage Pump Control Panel With Dry Contact Point For Building Management System</title>
		<link>https://maxitech.ca/water/product/1hp-20hp-sewage-pump-control-panel-with-dry-contact-point-for-building-management-system/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Mon, 11 Nov 2019 15:13:08 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=160</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE, ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L931-S</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>standard inner paper carton, 6 units in one outer paper carton with size: 69*58*46 cm</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Start Type:</th>
<td>Direct On Line (DOL)</td>
<th>Input Voltage:</th>
<td>AC380V, 50HZ, Three Phase</td>
</tr>
<tr class="bg_gray">
<th>Output Power:</th>
<td>1hp-20hp</td>
<th>Qty Of Controll:</th>
<td>Single Pump Control</td>
</tr>
<tr>
<th>Level Transmitter:</th>
<td>0.5-4.5V Level Transmitter, Analog Signal Output</td>
<th>Depth Value Setting &amp; Displaying:</th>
<td>Press Button And LCD Displaying Dynamic Depth Value</td>
</tr>
<tr class="bg_gray">
<th>After-Sale Service:</th>
<td>Available Modularized PCB Board</td>
<th>BMS System:</th>
<td>Available Dry Contact Point For BMS (Building Management System )</td>
</tr>
<tr>
<th>RS 485:</th>
<td>Available RS485 Port</td>
<th>OEM:</th>
<td>Available</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<p><strong>SINGLE</strong> <strong>INTELLIGENT PUMP CONTROL PANEL FO</strong><strong>R SEWAGE LIFTING </strong><strong>PUMP, WITH </strong><strong>THREE</strong><strong> PHASE, AC</strong><strong>38</strong><strong>0V/50HZ</strong></p>
<p><strong>Model </strong><strong>L931-S</strong><br />
Model L931-S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.</p>
<p>Typical usage scenarios include:<br />
-Chemical, petroleum, pharmaceutical, mining, paper making industry<br />
-Cement plant, steel plant, power plant, coal processing industry<br />
-Municipal waste water treatment plants<br />
-Drainage system<br />
-Municipal engineering<br />
-Construction site</p>
<p><strong>Application</strong><strong> &amp; </strong><strong>Control characteristic:</strong><br />
Connecting 0.5-4.5V level transmitter to replace liquid probe, float switch<br />
Pump start and stop according to different depth value setting</p>
<p><strong>Main technical data:</strong><br />
• Start type: Direct on line (DOL)<br />
• Qty of controller pump: single pump<br />
• Rated input voltage : AC380V, Three phase 50HZ/ 60HZ<br />
• Rated output power : 0. 75kw-4kw (1 hp-5. 5hp) &#8211; 5. 5kw-11kw (7.5hp-15hp) &#8211; 15kw (20hp)</p>
<table style="width: 271px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 149px;" colspan="2">Max Motor<br />
Output at 380V 3Ph</td>
<td style="width: 123px;">Relay<br />
Max Range(A)</td>
</tr>
<tr>
<td style="width: 45px;">HP</td>
<td style="width: 104px;">KW</td>
<td style="width: 123px;" rowspan="7">12A</td>
</tr>
<tr>
<td style="width: 45px;">1.0</td>
<td style="width: 104px;">0.75</td>
</tr>
<tr>
<td style="width: 45px;">1.5</td>
<td style="width: 104px;">1.1</td>
</tr>
<tr>
<td style="width: 45px;">2.2</td>
<td style="width: 104px;">1.5</td>
</tr>
<tr>
<td style="width: 45px;">3.0</td>
<td style="width: 104px;">2.2</td>
</tr>
<tr>
<td style="width: 45px;">5.0</td>
<td style="width: 104px;">3.7</td>
</tr>
<tr>
<td style="width: 45px;">5.5</td>
<td style="width: 104px;">4</td>
</tr>
<tr>
<td style="width: 45px;">7.5</td>
<td style="width: 104px;">5.5</td>
<td style="width: 123px;" rowspan="3">25A</td>
</tr>
<tr>
<td style="width: 45px;">10.0</td>
<td style="width: 104px;">7.5</td>
</tr>
<tr>
<td style="width: 45px;">15.0</td>
<td style="width: 104px;">11</td>
</tr>
<tr>
<td style="width: 45px;">20.0</td>
<td style="width: 104px;">15</td>
<td style="width: 123px;">32A</td>
</tr>
</tbody>
</table>
<p><strong>Product function </strong><br />
• Over load protection<br />
• Pump stalled protection<br />
• Dry run protection with sensor free<br />
• Under voltage protection<br />
• Over voltage protection<br />
• Rapid cycle protection<br />
• Open phase protection<br />
• Phase reversal protection<br />
• Pump shaft anti-rust protection<br />
• Three phase unbalance protection</p>
<p><strong>Product feature</strong><br />
• Pump start and stop depth value can be easily setting on the LCD screen<br />
• Pump last five faults record displaying<br />
• Pump accumulative running time displaying<br />
• Presenting one dry contact point (BA port) for BMS system<br />
• Present RS485 port (A+ / B－)<br />
• Remote monitor available (at option)</p>
<p><strong>Main installation data</strong><br />
• Working temperature: -25℃&#8211; +55℃<br />
• Working humidity: 20%&#8211;90%RH, no drips concreted<br />
• Degree of protection: IP54<br />
• Install position: Wall mounting<br />
• Unit dimension (L x W x H): 302 x 240x 120mm</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto / Manual Three Phase Pump Control Panel , Simplex Pump Controller</title>
		<link>https://maxitech.ca/water/product/auto-manual-three-phase-pump-control-panel-simplex-pump-controller/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Sun, 10 Nov 2019 20:16:20 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=154</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L931</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Phase:</th>
<td>Three Phase</td>
<th>Pump Controlled Quantity:</th>
<td>One Pump</td>
</tr>
<tr class="bg_gray">
<th>Enclosure Protection Grade:</th>
<td>IP54</td>
<th>Install Position:</th>
<td>Wall Mounting</td>
</tr>
<tr>
<th>Displaying ::</th>
<td>LCD Display</td>
<th>Liquid Level Transfer Distance:</th>
<td>≤1000m</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>Intelligent Digital Three Phase Water Pump Control Panel- Auto / Manual , One Button Calibration ,With LCD Displaying </strong></p>
<p style="color: tomato;"><strong>Product Brief:</strong></p>
<p>L931 Pump controller ,is a smart and intelligent three phase fully automatic pump controller with built-in water level control .<br />
It is very useful in water and waste water applications,be it water transfer ,tank filling ,tank emptying or even pressure boosting in Hydro-pneumatic applications.It comes in an ABS enclosure for weather-proof installation.it is suitable for Auto/Manual operation.</p>
<table style="width: 650px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 182px;"><strong>Model</strong></td>
<td style="width: 523px;">L931</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main technical data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Start type</strong></td>
<td style="width: 523px;">Direct on line</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Qty of controlled pump</strong></td>
<td style="width: 523px;">One pump</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated input voltage:</strong></td>
<td style="width: 523px;">AC380V Single phase<br />
50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Rated output power:</strong></td>
<td style="width: 523px;">0.75KW-15KW (1HP-20HP)</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Capacitor:</strong></td>
<td style="width: 523px;">N/M</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Protection Offered:</strong></td>
<td style="width: 523px;">Dry run<br />
Over load<br />
Transient surge<br />
Under voltage<br />
Over voltage<br />
Open phase<br />
Pump shaft rust protection<br />
Pump stalled<br />
Short circuit<br />
Over temp<br />
Three phase unbalance<br />
Phase reversal<br />
Repeated start</td>
</tr>
<tr>
<td style="width: 182px;"><strong>Application &amp;</strong><br />
<strong>Control chara</strong><strong>c</strong><strong>teristic</strong></td>
<td style="width: 523px;">Control and protect universal pump<br />
Using water level sensor or float switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 182px;"> <strong>Other features</strong></td>
<td style="width: 523px;">Push button calibration<br />
Memory function when power off &amp; recovery<br />
<strong>Interactive LCD Screen</strong><br />
<img loading="lazy" decoding="async" class="size-medium wp-image-156 aligncenter" src="http://maxitech.ca/wp-content/uploads/2019/11/20170913140655_63738-300x105.png" alt="" width="300" height="105" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170913140655_63738-300x105.png 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913140655_63738-600x211.png 600w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170913140655_63738.png 680w" sizes="auto, (max-width: 300px) 100vw, 300px" /></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Main installation data</strong></td>
<td style="width: 523px;"></td>
</tr>
<tr>
<td style="width: 182px;"><strong>Working temperature</strong><br />
<strong>Working humidity</strong><br />
<strong>Degree of protection</strong><br />
<strong>Install position</strong><br />
<strong>Unit dimension (L x W x H)</strong></td>
<td style="width: 523px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP22<br />
Wall mounting<br />
1 70× 1 55× 8.5mm</td>
</tr>
</tbody>
</table>
<p><strong>Main features:</strong><br />
■ Automatic stops the pump in the case of water shortage, protecting it from dry running<br />
without installing float switch or liquid probe in the well<br />
■ Auto / Manual switch<br />
■ Dynamic LCD displaying pump running state<br />
■ Push Button Calibration<br />
■ Pump Accumulative Running Time Displaying<br />
■ Pump Last Five Fault Record Displaying<br />
■ RS485 Communication<br />
■ Starts and stops the pump in accordance with the different liquid level or pressure setting</p>
<p><strong>FAQ</strong></p>
<ul style="list-style-type: square;">
<li>Can i have some samples ?</li>
</ul>
<p style="margin-left: 18.0000pt;">Yes ,we can send you samples for testing,contact us for details</p>
<p>2) What’s delivery time ?</p>
<p style="margin-left: 18.0000pt;">For standard pump control panel ,it usually takes about 7 working days;<br />
For non-standard,it usually takes 15-20days ,please contact us for details;</p>
<ul style="list-style-type: square;">
<li>Can I do OEM or ODM ?</li>
</ul>
<p style="margin-left: 18.0000pt;">Yes,we have our own engineering team and we do accept OEM and ODM,but there is ordering quantity requirement;</p>
<ul style="list-style-type: square;">
<li>How does your factory do the quality control ?</li>
</ul>
<p style="margin-left: 18.0000pt;">Our production process follow up the ISO standard and we control the product quality from the raw materials to the finished product,each of our control panel will be fully assembled and strictly tested before packing and shipping ;</p>
<ul style="list-style-type: square;">
<li>What is the approximate life time for your control panel /</li>
</ul>
<p style="margin-left: 18.0000pt;">The designed life time of control panel is 8 years ;</p>
<ul style="list-style-type: square;">
<li>what is your after sales service policy</li>
</ul>
<p style="margin-left: 18.0000pt;">According to the ordering quantity,we will give some free spare parts or controller for maintenance or replacement and we will give technical training;</p>
<ul style="list-style-type: square;">
<li>How can i trust you ?</li>
</ul>
<p style="margin-left: 18.0000pt;">We have being developing the pump control panel manufacturing and selling for 15 years ,now many pump supplier from China and overseas are using our controller to control and protect their pump and motor.</p>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Submersible Pump Protection Simplex Pump Controller , 3 Phase Pump Control Panel</title>
		<link>https://maxitech.ca/water/product/submersible-pump-protection-simplex-pump-controller-3-phase-pump-control-panel/</link>
		
		<dc:creator><![CDATA[itchadm]]></dc:creator>
		<pubDate>Sun, 10 Nov 2019 19:56:48 +0000</pubDate>
				<guid isPermaLink="false">http://maxitech.ca/?post_type=product&#038;p=149</guid>

					<description><![CDATA[<p class="txt_box" style="color: tomato;"><strong>Product Details:</strong></p>

<table class="tables data" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th width="35%">Certification:</th>
<td>CE/ISO</td>
</tr>
<tr>
<th width="35%">Model Number:</th>
<td>L531</td>
</tr>
<tr>
<th nowrap="nowrap" width="35%">Packaging Details:</th>
<td>Paper carton</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<div id="anchor_product_desc" class="no_product_detaildesc">
<p style="color: tomato;"><strong>Detailed Product Description</strong></p>
<table class="details_table" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th>Controlled Qty:</th>
<td>One Pump</td>
<th>Packing:</th>
<td>Paper Carton</td>
</tr>
<tr class="bg_gray">
<th>Carton Dimension:</th>
<td>69X58X46mm</td>
<th>PCS / CTN:</th>
<td>6PCS</td>
</tr>
<tr>
<th>Working Voltage:</th>
<td>380V-415V</td>
<th>Color:</th>
<td>White</td>
</tr>
</tbody>
</table>
<div class="details_wrap">
<div class="clearfix"></div>
<p><strong>Control Panel for Water Pump ,Three Phase , Input Voltage AC380V</strong></p>
<p style="color: tomato;"><strong>Technic parameter :</strong></p>
<table style="width: 568px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 284px;" rowspan="2">Control characteristic</td>
<td style="width: 284px;">Double liquid level control</td>
</tr>
<tr>
<td style="width: 284px;">Pressure control</td>
</tr>
<tr>
<td style="width: 284px;">Control method</td>
<td style="width: 284px;">Auto / Manual</td>
</tr>
<tr>
<td style="width: 284px;">Liquid level control charactersitic</td>
<td style="width: 284px;">Liquid probe / float switch</td>
</tr>
<tr>
<td style="width: 284px;">Pressure control characteristic</td>
<td style="width: 284px;">Pressure switch / pressure tank</td>
</tr>
<tr>
<td style="width: 284px;">Trip response time of overload</td>
<td style="width: 284px;">5sec-5min</td>
</tr>
<tr>
<td style="width: 284px;">Trip response tiime of dry run</td>
<td style="width: 284px;">6 sec</td>
</tr>
<tr>
<td style="width: 284px;">Recovery time of over load</td>
<td style="width: 284px;">30 min</td>
</tr>
<tr>
<td style="width: 284px;">Recovery time of under / over voltage</td>
<td style="width: 284px;">5 min</td>
</tr>
<tr>
<td style="width: 284px;">Recovery time of dry run</td>
<td style="width: 284px;">30 min</td>
</tr>
<tr>
<td style="width: 284px;">Trip voltage of over voltage</td>
<td style="width: 284px;">437V</td>
</tr>
<tr>
<td style="width: 284px;">Trip voltage of under voltage</td>
<td style="width: 284px;">301V</td>
</tr>
</tbody>
</table>
<p><strong>Company service:</strong><br />
1.Payment Terms :we can accept payment by T/T ,L/C,PAYPAL<br />
2.Delivery Terms :by sea ,by air ,DHL,TNT,UPS,FEDEX</p>
<p><strong>Our advantages :</strong><br />
As the manufacturer of intelligent pump controller and pump motor starter products ,we have selling experiences in this field for more than 10 years ,our main market including Southest Asia ,Africa ,South America and our products sells very well both in domestic and overseas market due to it’s novelty design and good performance .<br />
we can accept customized products becasue we have our own research and development department ;<br />
we can supply competitive price becasue we are the factory ;<br />
we can supply technic support because we have experienced technic team.</p>
<p><strong>Typical usage scenarios include:</strong><br />
-Houses<br />
-Flats<br />
-Holidays houses<br />
-Farms<br />
-Water supply from wells<br />
-Irrigations of greenhouses, gardens, agriculture<br />
-Rain water reuse<br />
-Industrial plants<br />
-Waste water tank / Sewage sink</p>
<p><strong>Application :</strong></p>
<ol>
<li>Control and protect universal pump</li>
<li>Using water level sensor or float switch to control pump start and stop</li>
<li>Applied for water supply by liquid level control through float switch or liquid probe</li>
<li>Applied for water supply by pressure control through pressure switch and pressure tank</li>
<li>Applied for drainage by liquid level control through float switch or liquid probe</li>
</ol>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-152 aligncenter" src="http://maxitech.ca/wp-content/uploads/2019/11/20170911164738_12012-300x214.jpg" alt="" width="300" height="214" srcset="https://maxitech.ca/water/wp-content/uploads/2019/11/20170911164738_12012-300x214.jpg 300w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170911164738_12012-600x428.jpg 600w, https://maxitech.ca/water/wp-content/uploads/2019/11/20170911164738_12012.jpg 680w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p><strong>SINGLE PUMP CONTROL PANEL</strong></p>
<table style="width: 568px; word-wrap: break-word;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 568px;" colspan="2">General detail:</td>
</tr>
<tr>
<td style="width: 164px;">Model</td>
<td style="width: 398px;">L531</td>
</tr>
<tr>
<td style="width: 164px;">Main technical data</td>
<td style="width: 398px;"></td>
</tr>
<tr>
<td style="width: 164px;">.Start type</td>
<td style="width: 398px;">Direct on line</td>
</tr>
<tr>
<td style="width: 164px;">. Qty of controlled pump</td>
<td style="width: 398px;">Single pump</td>
</tr>
<tr>
<td style="width: 164px;">. Rated input voltage:</td>
<td style="width: 398px;">AC380V Three phase</p>
<p>50HZ/ 60HZ</td>
</tr>
<tr>
<td style="width: 164px;">. Rated output power:</td>
<td style="width: 398px;">0. 75kw-4kw (1 hp-5. 5hp)<br />
5. 5kw-11kw (7.5hp-15hp)15kw (20hp)</td>
</tr>
<tr>
<td style="width: 164px;">Protection function</td>
<td style="width: 398px;">Over load protection<br />
Pump stalled protection<br />
Dry run protection<br />
Under voltage protection<br />
Over voltage protection<br />
Repeat start protection<br />
Open phase protection</td>
</tr>
<tr>
<td style="width: 164px;">Application &amp;<br />
Control characteristic</td>
<td style="width: 398px;">Control and protect universal pump<br />
Using water level sensor ,float switch or pressure switch to control pump start and stop<br />
Applied for water supply by liquid level control through float switch or liquid probe<br />
Applied for water supply by pressure control through pressure switch and pressure tank<br />
Applied for drainage by liquid level control through float switch or liquid probe</td>
</tr>
<tr>
<td style="width: 164px;">Other features</td>
<td style="width: 398px;">Pump last five faults record displaying<br />
Pump accumulative running time displaying<br />
Pump shaft anti-rust<br />
Presenting one dry contact point (BA port)<br />
Present RS485 port<br />
Present user remote monitor<br />
LCD screen locked function under Auto state</td>
</tr>
<tr>
<td style="width: 164px;">Main installation data</td>
<td style="width: 398px;"></td>
</tr>
<tr>
<td style="width: 164px;">Working temperature<br />
Working humidity<br />
Degree of protection<br />
Install position<br />
Unit dimension (L x W x H)</td>
<td style="width: 398px;">-25℃&#8211; +55℃<br />
20%&#8211;90%RH, no drips concreted<br />
IP54<br />
Wall mounting<br />
250×197×114mm</td>
</tr>
</tbody>
</table>
<div class="clearfix10"></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
